RUD conveyor technology - Retrofitting of one belt bucket elevator

Retrofitting of one belt bucket elevator

Description of the problem:

Severe conveying problems due to significant differences between assumed and actual product specification.

Assumed: Gypsum, 0-50 mm, destroyable, 10% moisture, non sticky

Actual: Gypsum, 0-80 mm, not destroyable, very wet, extremely sticky
    => Clogged buckets
    => elevator overflow
    => frequent shut downs
    => low capacity  

RUD Solution:

Exchange of stainless steel buckets by stainless steel buckets with flexible rubber bottom and scraper teeth.

Result:

Continuous conveying performance and full required capacity.