RUD conveyor technology - Retrofitting of one belt bucket elevator
Description of the problem:
Severe conveying problems due to significant differences between assumed and actual product specification.
Assumed: Gypsum, 0-50 mm, destroyable, 10% moisture, non sticky
Actual: Gypsum, 0-80 mm, not destroyable, very wet, extremely sticky
=> Clogged buckets
=> elevator overflow
=> frequent shut downs
=> low capacity
RUD Solution:
Exchange of stainless steel buckets by stainless steel buckets with flexible rubber bottom and scraper teeth.
Result:
Continuous conveying performance and full required capacity.